Ce-niehoff-co 100: Regulator Upgrade Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Ce-niehoff-co 100: Regulator Upgrade. C.E. Niehoff & Co. 100: Regulator Upgrade User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 1
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
II0004BPage 1 of 1
Series 100 Alternators
Installation Instructions
C. E. Niehoff & Co
.
BRUSHLESS ALTERNATORS
Voltage Regulator Upgrade
A2-436 regulator with light terminal –
Light Relay
L Terminal
(brown wire)
Figure 1 - Series 100 Wiring
B– Terminal
(white wire)
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
100 Series – A1-115, A1-125, A1-126, A1-127, A1-150,
A1-151, A1-160, A1-161, A1-163, A1-164, A1-165
,
C127, C166
N1028, N1029, N1030, N1034, N1035, N1041, N1042,
N1043, N1046, N1051, N1052, N1053, N1055, N1056,
N1058, N1059, N1060, N1061, N1062, N1063, N1065,
N1066, N1067, N1068, N1071, N1072, N1074, N1087,
N1088
, N3035, N7083
1. Remove alternator cover and existing voltage
regulator. Also remove heat sink from front of
alternator.
2. From rear of alternator, feed non-crimped end of
new green wire through slot near R terminal on
new regulator.
A1-165 and N1088 — green jumper wire
is not required. Connect black E lead from
shell E terminal to R terminal of new regula-
tor. Y terminal connection is not used.
3. Cut wire to proper length. Install sleeve, strip
wire, then crimp and solder larger terminal to
end of wire.
4. Re-install heat sink, connect new green wire
to phase terminal closest to output terminal. Do
not attach this wire to phase terminal with more
than two wires already attached.
5. Install new regulator on alternator and finish
wiring as shown in Figure 1.
6. At rear of alternator, attach new green wire to
back of R terminal.
7. On INSIDE of alternator cover, use supplied
template (II0005A) to cut new opening in cover:
a) Drill 1/8” pilot hole, then 9/16” hole.
b) Deburr new hole to prevent damaging
new switch on new circuit board.
8. Re-install alternator cover.
R Terminal
(new green wire)
Y Terminal
(brown wire)
B+ Terminal
(red wire)
Field – Terminal
(white wire)
This symbol is used in these instruc-
tions to indicate presence of hazards
that will or can cause minor personal injury or property
damage.
CAUTION
Voltage Select Switch Position
A2-436 and A2-437 Regulators
Position 1 13.8 V
Position 2 14.2 V
Position 3 14.6 V
Position 4 14.6 V
Do not allow
Y terminal
to touch alternator cover upon
reassembly. Replace existing terminal
with smaller terminal included in package.
Install sleeve, then crimp and solder smaller
terminal to wire.
CAUTION
Voltage Selector Switch
Vue de la page 0
1

Résumé du contenu

Page 1 - Series 100 Alternators

II0004BPage 1 of 1Series 100 AlternatorsInstallation InstructionsC. E. Niehoff & Co.BRUSHLESS ALTERNATORS Voltage Regulator Upgrade➛A2-436 regulat

Commentaires sur ces manuels

Pas de commentaire