Page 1 of 1
C722/C722-1 Alternators
Installation Instructions
C. E. Niehoff & Co
.
BRUSHLESS ALTERNATORS
This symbol is used to indicate
presence of hazards that can cause
minor property damage.
CAUTION
1. Install alternator as shown in Figure 1. Alternator
has two pairs of mounting lugs, so it can be
either right or left mounted. One of the oppo-
site mounting lugs can be used for tensioner.
When adjusting belt tension, mounting foot
hardware must be loosened. After belt tension is
adjusted or when mounting alternator, tighten
drive end mounting hardware before anti-drive
end hardware.
Slip bushing located in anti-drive
end mounting lug must be
securely tightened against
alternator mounting bracket
on engine. Failure to do so can
result in broken mounting lugs.
a. Use hardened washers between aluminum
surfaces and bolt heads and nuts.
b. OEM units are shipped with pulley, hardened
washer and locknut installed.
c. Aftermarket units are shipped with shaft
collar, hardened washer and locknut. Remove
and discard shaft collar. Install pulley and
furnished hardened washer.Torque locknut to
163 Nm/120 lb. ft.
Figure 1 - C722 Alternator Installation Details
CAUTION
TT
TT
T
Hardened washer
TT
TT
T
d. Follow vehicle manufacturer’s recommendations
for belt tension.
2. All cabling, wiring or conduit must be supported
within 305 mm/12 in. of termination on alternator.
Mounting screws on cable clamp should be torqued
to 15 Nm/130 lb. in.
3. Choose wire gauge capable of handling maximum
alternator output with no more than 0.4 V drop on
each leg from alternator to battery.
4. Regulator is furnished on OEM units and is supplied
separately by request with aftermarket units. Mount-
ing screws on regulator should be torqued to 8.5
Nm/75 lb. in.
5. Regulator electrical connections:
a. Make sure alternator-to-regulator harness
plug is secure in regulator receptacle.
b. A2-212 regulator has R (or W) and D+ 6mm
stud terminals, and an E 5mm stud terminal.
Torque terminal nuts to 4.5 Nm/40 lb. in.
Make sure regulator wiring is
connected to the correct terminals
otherwise permanent damage will
occur. R (or W) terminal has voltage
limiter that limits output voltage to
8V peak. Output voltage frequency
(Hz) = alternator rpm/10.
12mm/0.50 Locknut –
torque to
88 Nm/65 lb. ft.
Slip bushing must be tightened against
bracket — see “CAUTION” above
TT
TT
T
Bracket
on engine
B– terminal 10mm locknut –
torque to 15 Nm/11 lb. ft.
12mm x1.75 bolt –
torque to 32 Nm/24 lb. ft.
Washer
Battery output
cable terminal
(AWG 0000)
Lockwasher
Insulator
TT
TT
T
TT
TT
T
TT
TT
T
TT
TT
T
TT
TT
T
C722
ADE View
Alternator B+
Terminal Stud
C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633
Regulator mounting screws –
torque to
8.5 Nm/75 lb. in.
TT
TT
T
Alternator has two pairs of mounting lugs, so it
can be either right or left mounted. One of the
opposite mounting lugs can be used for
tensioner.
CAUTION
Vue de la page 0
1

Résumé du contenu

Page 1 - C722/C722-1 Alternators

II0062BPage 1 of 1C722/C722-1 AlternatorsInstallation InstructionsC. E. Niehoff & Co.BRUSHLESS ALTERNATORSThis symbol is used to indicatepresence

Commentaires sur ces manuels

Pas de commentaire