TG0021A
Table of Contents
Section 1: Wiring Diagram...................................... 2
Section 2: Basic Troubleshooting ........................... 3
Section 3: Advanced Troubleshooting............... 4 – 5
Battery Conditions
Until temperatures of electrical
system components stabilize, these
conditions may be observed during cold start voltage tests.
Maintenance/low maintenance battery:
Immediately after engine starts, system volts are
lower than regulator setpoint with medium amps.
3-5 minutes into charge cycle, higher system volts
and reduced amps.
5-10 minutes into charge cycle, system volts are
at, or nearly at, regulator setpoint, and amps are
reduced to a minimum.
Low maintenance battery has same characteris-
tics with slightly longer recharge times.
Maintenance-free battery:
Immediately after engine start, system volts are
lower than regulator setpoint with low amps.
15-30 minutes into charge cycle, still low volts
and low amps.
15-30 minutes into charge cycle, volts increase
several tenths. Amps increase gradually, then
quickly to medium to high amps.
20-35 minutes into charge cycle, volts increase
to setpoint and amps decrease.
High-cycle maintenance-free battery:
These batteries respond better than standard
maintenance-free. Charge acceptance of these
batteries may display characteristics similar to
maintenance batteries.
NOTICE
Hazard Definitions
These terms are used to bring attention to presence of hazards
of various risk levels or to important information concerning
product life.
Indicates presence of hazards that
will or can cause minor personal
injury or property damage.
Indicates special instructions on
installation, operation or mainte-
nance that are important but not
related to personal injury hazards.
CAUTION
NOTICE
N1233 Series Troubleshooting Guide
for N1233-2 Alternator
Charge Volt and Amp Values
The volt and amp levels are a function of the battery-
state of charge. If batteries are in a state of discharge,
as after extended cranking time to start the engine,
the system volts, when measured after the engine is
started will be lower than the regulator set point and the
system amps will be high. This is a normal condition for
the charging system. The measured values of system
volts and amps will depend on the level of battery dis-
charge. In other words, the greater the battery discharge
level the lower the system volts and higher the system
amps will be. The volt and amp readings will change,
system volts reading will increase up to regulator set
point and the system amps will decrease to low level
(depending on other loads) as the batteries recover and
become fully charged.
Low Amps: A minimum or lowest charging system
amp value required to maintain battery state of
charge, obtained when testing the charging system
with a fully charged battery and no other loads
applied. This value will vary with battery type.
Medium Amps: A system amps value which can
cause the battery temperature to rise above the
adequate charging temperature within 4-8 hours of
charge time. To prevent battery damage the charge
amps should be reduced when battery temperature
rises. Check battery manufacturer’s recommenda-
tions for proper rates of charge amps.
High Amps: A system amps value which can cause
the battery temperature to rise above adequate
charging temperature within 2-3 hours. To prevent
battery damage the charge amps should be reduced
when the battery temperature rises. Check battery
manufacturer’s recommendations for proper rates of
charge amps.
Battery Voltage: Steady-state voltage value as meas-
ured with battery in open circuit with no battery
load. This value relates to battery state of charge.
Charge Voltage: A voltage value obtained when the
charging system is operating. This value will be
higher than battery voltage and must never exceed
the regulator voltage set point.
B+ Voltage: A voltage value obtained when measur-
ing voltage at battery positive terminal or alternator
B+ terminal.
Surface Charge: A higher than normal battery volt-
age occurring when the battery is removed from
a battery charger. The surface charge must be
removed to determine true battery voltage and state
of charge.
Significant Magnetism: A change in the strength or
intensity of a magnetic field present in the alternator
rotor shaft when the field coil is energized. The
magnetic field strength when the field coil is ener-
gized should feel stronger than when the field is not
energized.
Voltage Droop or Sag: A normal condition which
occurs when the load demand on the alternator is
greater than rated alternator output at given rotor
shaft RPM.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1

Page 1TG0021ATable of ContentsSection 1: Wiring Diagram... 2Section 2: Basic Troubleshooting ...

Page 2 - Section 1: Wiring Diagrams

Page 2TG0021ASection 1: Wiring DiagramsFigure 2 — N1233-2 Alternator with N3140 RegulatorFigure 1 — N1233-2 Alternator Terminals(N3140 Regulator Attac

Page 3 - No Voltage Output

Page 3TG0021ASection 2: Basic TroubleshootingD. Basic Troubleshooting1. Inspect charging system components fordamageCheck connections at B– cable, B+

Page 4 - PIN CONNECTIONS

Page 4TG0021ASection 3: Advanced TroubleshootingSelf-energized alternator may have lost magnetism. Touch steel tool to shaft to detectany magnetism. I

Page 5

Page 5TG0021ASection 3: Advanced TroubleshootingYesNoAlternator is defective.With engine off, unplug alternator-to-regulator harness. Connect DMM red

Page 6

Page 6TG0021ANotes

Page 7

Page 7TG0021ANotes

Page 8

Page 8TG0021AIf you have questions about your alternator or any of these test procedures, or if you need to locate a Factory Authorized Service Distri